Frontier in Medical & Health Research
DIAGNOSTIC ACCURACY OF FOCUSED ASSESSMENT WITH SONOGRAPHY IN TRAUMA PERFORMED BY EMERGENCY MEDICINE VERSUS RADIOLOGY RESIDENTS IN BLUNT ABDOMINAL TRAUMA
PDF

Keywords

Blunt abdominal trauma, Diagnostic accuracy, Emergency medicine, Focused assessment with sonography for trauma, Point-of-care ultrasound.

How to Cite

DIAGNOSTIC ACCURACY OF FOCUSED ASSESSMENT WITH SONOGRAPHY IN TRAUMA PERFORMED BY EMERGENCY MEDICINE VERSUS RADIOLOGY RESIDENTS IN BLUNT ABDOMINAL TRAUMA. (2025). Frontier in Medical and Health Research, 3(4), 1437-1444. https://fmhr.net/index.php/fmhr/article/view/3890

Abstract

Objective: To compare the diagnostic accuracy of FAST performed by emergency medicine residents (EMRs) and radiology residents (RRs) for detecting intraperitoneal free fluid in blunt abdominal trauma.

Study Design: Comparative cross-sectional diagnostic-accuracy study.

Settings: Accident and Emergency Department, Jinnah Postgraduate Medical Centre, Karachi.

Period: Four months from January 2025 to April 2025.

Material & Methods: Independent, blind FAST examinations by an Emergency Medicine Resident (EMR) and a Radiology Resident (RR) were performed on 276 patients, aged 16-65 years, before a contrast-enhanced computed tomography (CECT) scan scheduled to occur within 6 hours. For each assessment, sensitivity, specificity, predictive values, and accuracy were considered. The exact McNemar test was used to compare paired accuracy, and descriptions of agreement were assessed with Cohen's Kappa.

Results: CECT was positive for free fluid in 49/276 patients (17.8%). EMR-FAST identified 44 true positives (TP), 224 true negatives (TN), 3 false positives (FP), and 5 false negatives (FN). Sensitivities, specificities and accuracy for EMR-FAST were 89.8%, 98.7% and 97.1%, respectively. RR-FAST identified 47 TL, 225 TN, 2 FP and 2 FN. Sensitivities, specificities and accuracy for RR-FAST were 95.9%, 99.1% and 98.6%, respectively. The difference in accuracy, 1.4%, was not significant (exact McNemar p = 0.388). The inter-operator agreement was 95.7% with a kappa score of 0.849.

Conclusion: Based on the findings, the accuracy of the EMR-FAST was high, and agreement with the RR-FAST was substantial. For EMR-FAST, the negative predictive value was also high, but FAST should not be considered a replacement for CECT in the presence of a high clinical index of suspicion.